NATURAL CAPITAL: ENVIRONMENTAL IMPACT

continued

Current energy and carbon emission savings initiatives

INITIATIVE

OBJECTIVE

PROGRESS/CURRENT ACTIVITIES

At Clearwater Mall, phase 2 PV plant

increased to 1 500kWh and

commissioned August 2015

Reduce carbon emissions and reliance on the

grid

Total energy produced by phase 1 and 2 from

1 July 2015 to end April 2016 is 1,9GWh

Capital replacement programme

Ensures capital equipment at the end of its

lifecycle is replaced with energy-efficient

equipment against the following criteria:

non-ozone-depleting refrigerant gas; reverse

cycle heating instead of electrical element

heating; and performance co-efficient 3,5 or

better

All capital replacements are approved by the

national technical manager

At Somerset Mall, three package units were

replaced in the review period using non-ozone-

depleting R410 refrigerant and with unit

performance co-efficients of 3,6. At Canal Walk,

only one-third of planned units (32 units) were

replaced with R410 refrigerant and energy-

efficient inverter units. The balance was rolled

over to FY17.

Modify thermostat set points and

supply temperature for chiller water

Lower energy costs in winter and summer

Building management systems upgraded at

CapeGate and Somerset Mall

Variable speed drives (VSDs) for

heating, ventilation and AC systems

Match speed to required output to reduce

consumption

Two faulty VSD drives replaced at CapeGate.

VSD drives installed where practical

LED lighting and occupancy sensors

Improve lamp life and reduce required power

factor correction

LED outside parking lighting installed at

Woodlands Boulevard and Atterbury Value Mart

Implement preventive maintenance

programmes on AC equipment

Ensure optimal operation of equipment

National service level agreement signed with third

party for seven sites. Regional agreements signed

for Pretoria sites. Remaining sites have signed

agreements with local contractor or agent. All

sites now covered by service level agreements

Peak energy demand reduction

Reduce power consumption in peak periods

(premium tariff) and avoid expensive peaks,

reducing the cost of consumption

Solar PV at Clearwater has reduced peak demand

from 8 200kVA to under 7 000kVA. All power factor

units serviced under contract, reducing kVA

Water efficiency initiatives

The table below highlights ongoing opportunities to manage water more efficiently.

INITIATIVE

OBJECTIVE

CURRENT ACTIVITIES

PROGRESS

Smart metering

Improve measuring and

monitoring of water

consumption and identify leaks

from unusual ow patterns

Anomalies immediately agged,

limiting risk and consequential loss

Accurately tracking consumption

patterns optimises nancial bene ts

of time-of-use tariff

Balancing sub-meters back to bulk

meter at all times to ag any bypassing

Bulk check meters installed at

certain sites

Fire system water

consumption

Identify leaks and illegal use of

water

Save water and avoid abuse of

infrastructure

All buildings monitored